ALA Series |
TV-4 rated (UL / CSA). Ideal for power supply inrush current requirements. |
2a |
3A 125VAC, 5A 277VAC |
125VAC, 277VAC |
Single Side Stable |
530mW |
Buy Now
|
ALE Series |
16A rating with excellent heat resistance. Available Class B and Class F coil insulation. 8mm minimum creepage and clearance distance between contact and coil. |
1a |
16A 277VAC |
277VAC |
Single Side Stable |
200mW (standard), 400mW (high sensitivity) |
Buy Now
|
ALF Series |
20A rating. Ideal for compressor and inverter loads. High insulation resistance. |
1a |
20A 250VAC |
250VAC |
Single Side Stable |
900mW |
Buy Now
|
ALZ Series |
Low profile design (15.7mm height). 16A contact rating. High insulation resistance. Excellent heat resistance compliant with EN60335-1 GWT. |
1a, 1c |
16A 250VAC |
440VAC |
Single Side Stable |
400mW |
Buy Now
|
HE Series |
TV-10 and TV-15 rated. Excellent resistance to welding. 30A contact capacity. 200,000 operations electrical life rating. |
1a, 2a |
30A 277VAC (1a) |
30VDC, 277VAC |
Single Side Stable |
1.92W (DC coil), 1.7VA to 2.7VA (AC coil) |
Buy Now
|
25A 277VAC (2a) |
HE-PV Series |
2.5mm contact gap. Complies with solar inverter requirement (European PV standard VDE0126). EN61810-1 certified with 2.5kV surge breakdown voltage between contacts. |
1a, 1a (high capacity) |
35A 250VAC (1a) |
250VAC |
Single Side Stable |
1920mW |
Buy Now
|
48A 250VAC (1a high capacity) |
JM Series |
20A rating ideal for compressor and motor control. 80A inrush capability. High contact pressure, forced opening mechanism, and forced wiping mechanism. |
1a |
20A 250VAC |
250VAC |
Single Side Stable |
900mW |
Buy Now
|
JQ Series |
High electrical noise immunity. 10A switching capacity. 8,000V surge resistance between contact and coil. Class B coil insulation available. |
1a, 1a (high capacity), 1c, 1c (high capacity) |
1a standard: 2A 250VAC, 5A 30VDC/125VAC |
250VAC, 110VDC (0.3A) |
Single Side Stable |
200mW (1a, 1a high capacity), 400mW (1c, 1c high capacity) |
Buy Now
|
1c standard NO: 2A 250VAC, 3A 30VAC, 5A 125VAC |
1c standard NC: 1A 30VDC, 1A 250VAC, 2A 125VAC |
1a high capacity: 5A 30VDC/250VAC, 10A 125VAC |
1c high capacity NO: 5A 30VAC/250VAC, 10A 125VAC |
1c high capacity NC: 1A 30VDC, 2A 250VAC, 3A 125VAC |
JS Series |
TV-5 rated 10A contact capacity. Class B and Class F coil insulation available. EN60335-1 GWT compliant option. |
1a, 1c, 1a (long life) |
1a, 1c: 5A 30VDC, 6A 277VAC, 10A 125VAC, 10A 250VAC (NO) |
250VAC, 100VDC (0.5A) |
Single Side Stable |
360mW |
Buy Now
|
1a (long life): 10A 250VAC/277VAC, 5A 30VDC |
JTN Series |
30A switching capacity. Class F coil insulation. Sealed construction. |
1a, 1c |
20A 277VAC (1a, 1c NO) |
277VAC |
Single Side Stable |
800mW |
Buy Now
|
10A 277VAC (1c NC) |
JTV Series |
30A contact rating. 6,000V surge resistance. Class F coil insulation standard. Sealed and dust cover construction. |
1a, 1c |
30A (1a only) |
277VAC |
Single Side Stable |
1000mW |
Buy Now
|
20A 277VAC (1a, 1c NO) |
10A 277VAC (1c NC) |
JVN Series |
Ideal for heater control. Designed to limit contact terminal heat. 16A capacity. Compact and flat housing: 22(L) x 16(W) x 10.9(H) mm. |
1a |
10A 30VDC, 125VAC/277VAC |
30VDC, 277VAC |
Single Side Stable |
200mW (4.5 to 48VDC), 600mW (100VDC) |
Buy Now
|
16A 125VAC |
JW Series |
Ideal for power supplies. High dielectric strength for transient protection. 10A nominal switching capacity. TV-5 rating available. |
1a, 1c, 2a, 2c |
5A 30VDC/250VAC (1a, 1c, 2a, 2c) |
250VAC, 30VDC |
Single Side Stable |
530mW |
Buy Now
|
10A 250VAC/30VDC (1a, 1c) |
LF-G Series |
22A/31A rating for solar inverters. 1.5mm contact gap complies with VDE0126 standard. Coil holding voltage reduction up to 35% of nominal coil voltage for energy savings. |
1a |
22A 250VAC |
250VAC |
Single Side Stable |
1400mW |
Buy Now
|
31A 250VAC |
LKP Series |
Power version of LK series. TV-5 rating. 10,000V surge resistance. 6mm minimum creepage and clearance distance between contact and coil. |
1a |
10A 277VAC, 5A 30VDC |
30VDC, 277VAC |
Single Side Stable |
530mW |
Buy Now
|
LQ Series |
Compact design with 10A rating targets home appliances. Class B and F insulation. 8,000V surge voltage between contacts and coil. 4,000V breakdown voltage between contacts and coil. |
1a, 1c |
1a: 10A 125VAC, 5A 277VAC, 5A 30VDC |
250VAC |
Single Side Stable |
200mW (1a), 400mW (1c) |
Buy Now
|
1c: 10A 125 VAC (NO), 5A 277VAC (NO), 5A 30VDC (NO), 3A 125VAC (NC), 2A 277VAC (NC), 1A 30 VDC (NC) |
PA Series |
5A slim housing designed for sockets. 120mW nominal operating power (lower power supply requirements). 4,000V surge resistance. |
1a |
5A 250VAC/30VDC |
110VDC, 250VAC |
Single Side Stable |
120mW (5VDC to 18VDC), 180mW (24VDC) |
Buy Now
|
PF Series |
6A slim design. Reinforced insulation standard EN/IEC 61810-1. 6,000V surge breakdown between contact and coil. |
1a, 1c |
6A 250VAC |
110VDC, 250VAC |
Single Side Stable |
170mW (5VDC to 24VDC), 217mW (48VDC), 175mW (60VDC) |
Buy Now
|
PQ Series |
5A compact housing designed for sockets. 8,000V surge resistance between contact and coil. |
1a |
5A 250VAC/30VDC |
110VDC (0.3A), 250VAC |
Single Side Stable |
200mW |